Specification
Model | LLX-DWL-15 | LLX-DWL-20 | LLX-DWL-24 | LLX-DWL-30 | LLX-DWL-42 | LLX-DWL-60 | LLX-DWL-80 | LLX-DWL-100 | LLX-DWL-120 |
Power (W) | 15 | 20 | 24 | 30 | 42 | 60 | 80 | 100 | 120 |
Voltage (V) | 110–277 | 110–277 | 110–277 | 110–277 | 110–277 | 110–277 | 110–277 | 110–277 | 110–277 |
Hz | 50/60 | 50/60 | 50/60 | 50/60 | 50/60 | 50/60 | 50/60 | 50/60 | 50/60 |
CCT (K) | 4000-5700 | 4000-5700 | 4000-5700 | 4000-5700 | 4000-5700 | 4000-5700 | 4000-5700 | 4000-5700 | 4000-5700 |
Luminous Flux @5000K, 120° (LM) | 1350 | 1800 | 2160 | 2700 | 3800 | 5700 | 7600 | 10000 | 12000 |
CRI | 70 | 70 | 70 | 70 | 70 | 70 | 70 | 70 | 70 |
Super bright chip | Cree | Cree | Cree | Cree | Cree | Cree | Cree | Cree | Cree |
Driver | Universelite | Universelite | Universelite | Universelite | Universelite | Universelite | Universelite | Universelite | Universelite |
Material | AL+PC | AL+PC | AL+PC | AL+PC | AL+PC | AL+PC | AL+PC | AL+PC | AL+PC |
Suitable Locations | wet | wet | wet | wet | wet | wet | wet | wet | wet |
Beam angle | 110° | 110° | 110° | 110° | 110° | 110° | 110° | 110° | 110° |
Size(MM) | 209*134*122 | 209*134*122 | 209*134*122 | 257*140*160 | 257*140*160 | 320*190*253 | 320*190*253 | 400*205*268 | 400*205*268 |
Life Time (H) | 50000 | 50000 | 50000 | 50000 | 50000 | 50000 | 50000 | 50000 | 50000 |
IMPORTANT SAFETY INFORMATION:
Input Voltage: AC 100-277V, 50/60Hz
Working Temperature: -25ºC~40ºC
This fitting must be wired in accordance with the National Electrical Code and applicable local codes and ordinances.
Installation and servicing this fitting should be performed by qualified electrician only.
Before installation or maintenance, turn off electric power and allow the fitting to be cool.
Proper grounding is required to insure personal safety. Carefully observe grounding procedure under installation section.
Ensure all electrical connections are secure & that there are no loose strands.
Install the fitting in a well-ventilated environment, keep away from corrosive/explosive materials, flammable gas or electric dust.
Violent shaking or impact should be avoided when the fitting is working.
To weather proof your outdoor installation, be sure to seal all holes, conduit plugs with silicone caulking.
SUGGESTED METHOD OF INSTALLATION:
ALWAYS SWTICH OFF THE MAINS SUPPLY BEFORE INSTALLATION.
STEP 1: Take off mounting plate A from the fitting. (Fig. I)
STEP 2: Mount the mounting plate A to the Junction box in the wall. (Fig. II)
Place adhesive gasket first if necessary.
STEP 3: Hold the fitting, connect the wires and push the wires back to the junction box in the wall.
Seat the fitting on the mounting plate A and swing down into the place. (Fig.III)
STEP 4: Tighten the screws to make the fitting secured, apply silicone glue around the fitting where it touch the wall, for better sealing. (Fig. IV)
WIRING INSTRUCTION OF MAIN CABLE:
WARNING:
The product must be grounded and installed in accordance with the National Electrical Code and all local codes.
Failure to do so may increase the RISH OF PERSONAL INJURY, PROPERTY DAMAGE, FIRE AND DEATH.